VOC Emission Test Equipment
The coated stainless steel obviously improves the adsorption capacity of the high-boiling-point materials and polar compounds in test chamber. The chamber absorbs over 80% of tetradecane and 4-phenyl-1-cyclohexene.
The coated stainless steel obviously improves the adsorption capacity of the high-boiling-point materials and polar compounds in test chamber. The chamber absorbs over 80% of tetradecane and 4-phenyl-1-cyclohexene.
Testimony
This is the pictures in 100* magnification microscope with special-coated and uncoated in VOC Emission Equipment interior stainless steel (which has great mirror-finished surface treatment)
Special Coated in VOC Emission Equipment Interior Uncoated in VOC Emission Equipment Interior
The special invention about how to resolve the VOC recycling in VOC Emission Equipment has successfully applied in China,The United State and Japan.Till now, we are still applying for the patent in Europe.
Unique In United State
Unique In Japan
Technical Reference
Product Model | V-50 | V-100 | V-250 | V-500 | V-1000A | V-1000B | V-2000 |
Volume of chamber(W×D×H) cm | 56*30*30 | 63*40*40 | 70*60*60 | 102*70*70 | 158*80*80 | 91*100*110 | 200*110*90 |
Environmental temperature | 5~ 35°C | ||||||
Environmental humidity | ≤ 90% R.H | ||||||
Requirements for Environmental | Cleanliness No pollutant source in the surrounding environment TVOC 500µg/m³ | ||||||
Adjustable range of temperature | 10~ 40°C high temperature cleaning 250°C | ||||||
Adjustable range of humidity | 40~70%R.H.(20°C ~30°C ) | ||||||
Pressure | 10±5pa | ||||||
Temperature fluctuation | ±0.3°C ( Fluctuation) | ||||||
Temperature deviation | ±0.5 °C ( Deviation) | ||||||
Humidity fluctuation | ±2.5%R.H | ||||||
Humidity deviation | ±3% | ||||||
Air exchange rate | 0.2~2/h±5% ( Optional 0.2~3/h±5%) | ||||||
Air velocity | 0.1m/s 0.3m/s ( Range) | ||||||
Power | Alternating current 380V/50HZ three-phase power supply 4/5 wiring system | ||||||
Starting power | 5kw | 6kw | 8kw | 10kw | 15kw | 15kw | 20kw |
Operating power | 3kw | 3.4kw | 5kw | 6kw | 7kw | 7kw | 9kw |
Rate of recovery | Formaldehyde, octanol, 4 phenyl Cyclohexene, dodecane and tetradecane have a recovery rate larger than 80% | ||||||
Clean air system | Standard configuration | ||||||
Background concentration of VOC | Single VOC has a concentration smaller than 2µg/m³ ,T VOC 20µg m dust filtrated TVOC has a concentration smaller than 20µg/m³ |
Outward Appearance
Configurations
Operation Testing Methods
*GB18580-2001″ Formaldehyde Emission of Manmade Board and Its Products”
*GB18584-2001 “Indoor Decorating and Renovating Materials Limits of Harmful Substances in Wooden Furniture”
*Gb18587-2001 “Indoor Decorating and Renovating Materials Releasing Limitation of Harmful Substances from Carpet,Carpet Pad and Carpet Adhesive”
* ASTM D6007-02 “Standard Test Methods for Determination of Formaldehyde Concentration in Gases Released from Wood Products with Small Scale Environmental Chamber”
* ENV717-1 “Environmental Chamber Method for Measurement of Formaldehyde Emission of Manmade Board”
*EN13419-1 “Determination of VOCs Release quantity of Building products Chapter One The Method for Releasing and Testing the Environmental Chamber”
*HJ 571-2010 “Technical Requirements for Environmental Labeling Manmade Board and Its Products”
*HJ 566-2010 “Technical Requirements for Environmental Labeling Manmade Board and Its Products”
Reference Standards
*ASTM D5116-97 “Standard Guide for Determination of Organic Release from Interior Materials and Products with Small Scale Environmental Chamber”
*ASTM D6330-98 “Standard Operation for Determination of VOCs (Excluding Formaldehyde) Release from Wooden Board with Small Environmental Chamber under Specified Test Conditions”
*ASTM D6670-01 “Standard Operation for Determination of VOCs Release from Interior Materials and Products with Full Scale Environmental Chamber”
*ASTM E1333-96 “Standard Test Methods for Determination of Formaldehyde Concentration and Release Rate in Gases Released from Wood Products with Large Scale Environmental Chamber”
In 2009, the first time for IKEA to trying purchased two sets of simplewell’s VOC and Formaldehyde emission chamber;
In 2011, they supplemented 1 set VOC emission equipment from simplewell;
In 2013, Simplewell VOC emissions chamber performance upgraded that R&D stainless steel surface easy adsorption VOC problems, VOC cabin prevent adsorption coating treatment. All the 46 sets of VOC chamber sold for free replacement, two VOC emission chambers sold to IKEA also been free upgraded. As the upgraded chamber has great effect on test accuracy,and Simplewell always keeping his integrity management, so IKEA has third purchase. After the VOC emissions chamber upgraded, the IKEA company using our chamber data to compare with Weiss Technik chambers, then they very satisfied with our chamber, since then the IKEA company plan to purchase our VOC emission chamber more for they the products testing;
In 2014, IKEA supplemented 1set of 5M3 VOC emissions chamber and compared the test accuracy with it from 1M3 simplewell chamber,( because they need bigger chambers to meet the product requirements.) And also, the 5M3 testing result is good;
In 2015, IKEA supplemented supplement Simplewell VOC emissions chamber once more.
In 2017~ till now, the IKEA supplemented 7 sets of VOC emission chambers.
Until now, IKEA all the VOC test chambers supplied by Simplewell.
By the way: SGS bought more than 50sets chamber from Simplewell. And 2 years ago, TUV also bought 1set of our VOC emission chamber to test with Weiss Technik, the testing result not bad also. Now they are building a laboratory in Guangzhou plan to buy the VOC emission chambers from us too.