What are the design standards for formaldehyde and VOC environmental test chambers?
The environmental test chamber for 1 cubic meter of VOC emission is mainly applied to study the variation of VOC emissions in automotive interior parts, man-made panels and related light industrial products, and to detect the VOC emissions in automotive interior parts, man-made panels and related light industrial products, and to classify the tested products; To carry out comprehensive environmental index evaluation of indoor air quality according to indoor pollutant data or prediction models….
Chinese Standard
“Test method for physical and chemical properties of wood-based panels and decorative wood-based panels” (GB/T17657-2013)
“General technical requirements for air cabins for the detection of volatile organic compounds in furniture” GB 31107-2014
“Limits for Release of Harmful Substances in Interior Decoration Materials Carpets, Carpet Pads and Carpet Adhesives” (GB18587-2016);
“Technical Requirements for Environmental Labeling Products-Artificial Panels and Products” (HJ 571-2010);
“Indoor Decoration Materials-Formaldehyde Release Limits in Artificial Panels and Products” (GB 18580-2017);
“Indoor Air Quality Standard” (GB/T 18883-2002);
“Technical Requirements for Environmental Labeling Products-Waterborne Coatings” (HJ/T 201-2005);
“Technical Requirements for Environmental Labeling Products Adhesives” (HJ/T 220-2005)
“Technical Requirements for Environmental Labeling Products for Solvent-based Wood Coatings for Interior Decoration” (HJ/T 414-2007);
“Indoor Air-Part 9: Determination of Emitted Volatile Organic Compounds in Building Products and Furnishings-Test Chamber Method” (ISO 16000-9-2011);
“1M3 climate chamber for formaldehyde emission detection” (LY/T1980-2011)
“Standard for Release of Toxic and Hazardous Substances from Musical Instruments” (GB/T 28489-2012)
GB_T 29592-2013 Determination of Volatile Organic Compounds (VOC) and Aldehyde Compounds Released from Construction Adhesives
GB/T29899—2013 Test Method for Volatile Organic Compound Emissions in Wood-Based Panels and Products-Small Emission Chamber Method
JG-T 344-2011 Indoor Environmental Test Chamber for Construction Engineering
LY/T1980-2011 “Volatile Organic Compound (VOC) and Formaldehyde Emission Detection Box”
LY/T 1981-2011 formaldehyde emission gas analysis method detection box
GB18580-2017 “Limits of Formaldehyde Release in Artificial Panels and Products of Interior Decoration Materials”
HJ 571-2010 “Technical Requirements for Environmental Labeling Products-Artificial Panels and Products”
HJ 566-2010 “Technical Requirements for Environmental Labeling Products Wooden Toys”
HJ/T 400-2007 “Methods for sampling and determination of volatile organic compounds and aldehydes and ketones in vehicles”
European Standard
EN 13419-1 “Construction products-Determination of VOCs emission Part 1: Release test environment chamber method”
Test formaldehyde emission EN 717-1 “Environmental Chamber Method for Measuring Formaldehyde Emission from Artificial Panels”
BS EN ISO 10580-2012 “Elastic fabrics and laminate floor coverings. Volatile organic compound (VOC) emission test method”;
Japanese standard
JIS A1901-2009 “Determination of Volatile Organic Compounds and Aldehyde Emission in Building Materials—Small Climate Chamber Method”;
JIS A1912-2008 “Determination of Volatile Organic Compounds and Aldehyde Emissions in Building Materials—Large Climate Chamber Method”;
American Association for Testing and Materials Standards
ASTM D 5116-97 “Standard Guide for Determination of Organic Release in Indoor Materials and Products in Small-scale Environmental Chambers”
ASTM D 6330-98 “Standard Practice for the Determination of VOCs (In addition to Formaldehyde) in Wood Panels in a Small Environmental Chamber under Specified Test Conditions”
ASTM D 6670-01 “Standard Practice for Determining VOCs Released from Indoor Materials and Products by Full-scale Environmental Chamber”
ASTM D5116-97 “Standard Guide for the Determination of Organic Release in Indoor Materials and Products in Small-scale Environmental Chambers”
ASTM D6330-98 “Standard Practice for Determination of VOCs (Except Formaldehyde) Release from Wooden Panels in Small Environmental Chambers under Specified Test Conditions
ANSI/BIFMA M7.1-2011 Standard Test Method for VOC Release Rate in Office Furniture Systems, Components and Seats
ASTM E 1333-96 “Standard Test Method for Determination of Formaldehyde Concentration and Release Rate in Gas Released from Wood Products in Large Environmental Chambers”
ASTM D 6007-02 “Standard Test Method for the Determination of the Concentration of Formaldehyde in the Gas Released from Wood Products in a Small-scale Environmental Chamber”
International Standard
“1M3 climate chamber method to determine the amount of formaldehyde released from panels” (ISO 12460-1.2007)
“Indoor Air-Part 9: Determination of Emission of Volatile Organic Compounds Emitted by Building Products and Furniture-Emission Laboratory Method” (ISO 16000-9.2006)